Used Materials
Sheathing plates (EPS-XPS)

Expanded Polystyrene Foam and referred to as compressed. Oil is obtained, impregnation of the particles and as a result of adhesion. Predominantly produced in white, while those carbons in gray. Carbon insulation value (lambda value) increases. The carbon should preferably be 100%. Reflecting the thermal conductivity of carbon reduces heat rays.

XPS (Extruded polystyrene) foam becomes hard foam raw materials by adding a blowing agent into the softened color can be produced. The XPS hard foam material is difficult to comply with plaster and glue, so spills can occur. The surface is smooth, due to the problems experienced company began producing single-channel and dual-channel plates. It can also be flexible because it broke the surface in artçıl concussion. Breaking the wall plate with the anchors can be avoided, the only break of the plate mesh and plaster materials quality is unavoidable.

Rockwool Insulation (sheathing) Signs

After a glass fiber or moved to become molten and to hold together these fibers generally used polymer binder, open pore insulation (sheathing) it is material. Stone wool has a high density material, eps square meter weight is not preferred because it is so high and that the application difficult. Work is detailed and accurate, it is difficult to obtain a surface gauge setting. Because it is heavy enough adhesive and dowels brings an inextricable situation of the sleazy business use.

Thermal insulation (sheathing) Adhesive

Sheathing plates (EPS, XPS or rock wool) insulation (sheathing) systems, vertical surfaces or horizontal surfaces (on leave) polymer additives are used for the purpose of bonding mortar. In particular, there must be a very high quality of the adhesive in rockwool. Since it is the missing load, adhesive anchors are used as jacketing systems and quality should be applied correctly. It must be driven by applying plate and frame system should be implemented in the form of three points in the middle. Should not be a direct approximation to the floor with adhesive sheet to increase its effectiveness, it should be shifted to the side up to 10 cm after the wall is snapped.

Nail the sheathing

Sheathing plates (EPS, XPS or rock wool) insulation (sheathing) vertical surfaces and horizontal surfaces (the rise) is manufactured from physically hard plastic used to secure, broad-headed conservative supplies.

Reinforcement Mesh

Sheathing boards (EPS, XPS or rock wool) meet the pull out will occur in coated plaster stress and used to prevent cracking, eye size of at least 4 x 4 mm, usually net plaster woven glass fibers. Reinforcement is usually seen in the parts where the use of nets and spills cracking. Usually the file missing parts of the window are the centers used. File should be no gap between the tracks and applied to be put on top. Also one of the sheathing errors made in the application is to be put under the plaster or missing file or set, usually it does so because it came easy running application.

Thermal insulation (sheathing) Plaster Board

Sheathing panels (EPS, XPS or rock wool) combining results together with a continuous surface and the spaces formed surface of the file (applied to the bottom and on the net) is the material used for the plaster. Some of the brands in wrapping adhesive, and has been recommended by the manufacturer for this purpose. Artefacts on the boards and gaps with plaster is removed, the surface is rendered flat and decorative sheathing applicable. And decorative coating is applied after.

Decorative Coatings

Sheathing plates (EPS, XPS or rock wool) and jacketing systems and protect them from physical factors of building and atmospheric conditions are final layer materials used to impart decorative and aesthetic appearance. After the plaster is applied, whether it is the last floor as much detail and does not accept failure. Additional space can be recognized because it dries quickly in standby. So facade will be implemented by certain professional teams is important to be completed within the same day. From master to master because the surface roughness noticed craftsmanship recommended working close together, work together.

Netting Corner Profile

The coating system; building corners, window and door center to protect it from physical shocks and aluminum used to view gauge duty applications in plaster, made of PVC or net alkaline environment are resistant profile. You absolutely must have a net, some companies can use to escape from the cost of filesize. Do not let it, otherwise cracking and loss are inevitable.

Drainer Corner Profile

The coating system; balcony, climbing, building recesses, etc. in part to the lower floors, rain and other water currents and water intercept aluminum used to lower the floor, made of PVC or net alkaline environment are resistant profile. You absolutely must have a net, these profiles can also use it to escape from the cost filesize some companies. Do not let this case be used because it is where the water is cracking and spalling in the end result will be experienced kaçınılmazdır.hiç used inward loss from dirty pictures and ceiling of the forehead. After the peeling plaster concrete parts will begin to suffer.

Six sills Profile

The coating system; on the surface of the marble wall sheathing panels coated with the complete results of the lower window sills used on the bottom with no window. Marble windowsill flow out of the rain and snow water filtered through the windows down to the floor allows the flow from the wall. Mastic or off the bottom of the preceding windowsill placed in the column. Steels are profiles made of PVC or aluminum. In some buildings on the old marble windowsill placed 2cm to provide old original image. Even if jacketing applications after staying outside the old marble windowsills 2-3 cm is not enough. The important thing is to stay after jacketing applications inside the dropper in the lower sills channels, because these channels to flow to and from the wall of the water fall.

Profile of Water Discharge

The coating system; thermal insulation (thermal insulation) in the level of the beginning of the plate, protect the coating system of physical impact, the plaster application gauge and see the scales duties and into the surface water of the move away from the surface without entering into the system and insulation board living and allows to create a smooth line. All designed to allow them to be mechanically mounted to the wall and are manufactured from stainless steel or aluminum profile with a certain physical strength.

Dilatation Profile

The coating system; To compensate for expansion and contraction in the corners of the surface and expansion joints and profiles are manufactured in order to prevent cracking in artçıl concussion. The more damage will occur in any part of jacketing applications will dilatation profile of unused parts of the building structure in the coating surface of any independent act independently artçıl concussion although it will be seen on the other side.

Polyurethane Sealant

The coating system; external thermal insulation (sheathing) in the system with door & window frame connection section, profiles are used to prevent the formation of cracks. Protecting the chopping case (damage to the chassis and prevent contamination) and non-PVC protective belt types that are available. For this purpose, polyurethane sealant can be used instead of profile. In addition, this profile or mastic contains water leakage and also prevents water damage opener.

Insulation Tape

The coating system; and coping with structural elements such as windowsills, external thermal insulation (sheathing) in sections of the system combination, particularly against the rain water is used for the insulation purpose. 2-6 mm, depending on the place and purpose, as they are three different types to 3-9 mm and 5-12 mm gap width, special insulation tapes are available for similar purposes.

Plastic Wedge

The coating system; Plastics are used to compensate for the distance to the walls of the flooding profile ..

Plastic Konjektor

The coating system; In addition to the flooded areas of thermal expansion profiles and so on. The plastic profiles are used to compensate the effect lateral movement may occur.

Band corner

The coating system; To prevent cracks will occur in cutting corners, used for reinforcement, made of alkali-resistant glass fiber reinforcements are. 30 x 40 cm, 30 x 50 cm, 30 x 60 cm lArIndAdIrlAr. It can be used with the purchase of a ready manner, it can also be used to cut the net. One of the rare materials used in thermal insulation applications in Turkey. In fact there is no such product on the manufacturer of the product assortment, professional team who also uses this application by cutting part of the reinforcement mesh. The cut part can be applied by forming a 45 degree angle.